Brushless DC Water Pump DC55K
-
Drive external version Driver built-in version
Product Features
Product Name: Brushless DC Water Pump DC55K Weight: 0.52kg Model No.: DC55K Lifespan: ≥30000hContinuous Protection grade: IP68 Color: Black Certifications: CE,ROSH Housing Material: PPS+30%GF Noise level: ≤35dB Sealing: ≥0.5MPa(5kg) Insulation class: H级(180°) Principle of operation: Centrifugal pump Application: Cooling circulation systems Scope of use
Type of liquid used:
Oily media, water, acids, alkalis, salts and other fluids. Temperature of liquid used:
-30°—100°Non-submersible built-in three-phase plate / Submersible external three-phase plate
Speed control method:
*PWM speed control: amplitude 5V 50-800HZ can be customized.
*0-5V speed regulation
*Potentiometer speed regulation: resistance range 4.7K~20K
Type of power supply:
DC power supply, solar panel, battery Basic parameters (parameters can be customized)
Product Model DC55K-12170PWM
DC55K-12170VR
DC55K-12170VS
DC55K-12170S
DC55K-24250PWM
DC55K-24250VR
DC55K-24250VS
DC55K-24250S
PWM:PWM speed control (50-800HZ/5V)
VR:potentiometer speed control
VS:0~5V analog voltage signal speed control
S:Fixed speed
Rated Voltage 12V 24V DC Operating Voltage Range 10-18V
10-30V
Within this range, the pump can work normally Rated current 3.5A(4.5A)
2.7A(3.3A)
Closed outlet current (open pumping current) Input power 42W(54W)
65W(80W)
Closed outlet power (open pumping power) Maximum flow rate 470L/H
550L/H
Open outlet flow rate Maximum head 17M
25M
Static head Minimum input power 12V-5A
24V-4A
Description of additional functions
Jamming protection Pump stops working when jammed Water shortage/idling protection When the pump runs out of water or idles, the pump will cycle through stopping (8 seconds) and running (2 seconds), customizable protection strategies are available. Overload protection When the voltage is unstable or for other reasons exceeds the rated power of the pump, the pump will stop running. Reverse power connection When the positive and negative poles of the power supply are reversed, the pump stops running, and after reconnecting, it works normally. Pump driver built-in Suitable for external land use Pump driver external Suitable for high temperature or corrosive solution submersible installation Flow rate and head curve
Dimensional drawings
Parameter Test Installation Diagram
Note: This product does not have the function of self-priming, so when installing, you need to ensure that there is enough water in the gland cavity, that is, when installing, you need to ensure that the center of the pump is lower than the liquid level in the tank to ensure that the pump can operate normally!
-