Brushless DC Water Pump DC55A
-
Product Feature
Product Name: Brushless DC Water Pump DC55A Weight: 0.52kg Model: DC55A Lifespan: ≥30000hContinuous Protection Grade: IP68 Color: Black Accreditation: CE,ROSH Housing Materials: PPS+30%GF Noise: ≤35dB Sealing: ≥0.5MPa(5kg) Insulation class: H级(180°) Principle of operation: Centrifugal pump Application: Cooling circulation systems, pressurized water distribution systems Scope of use
Type of liquid used:
Oily media, water, acids, alkalis, salts and other fluid liquids. Temperature of liquid used:
-30°—100°Non-submersible built-in three-phase plate / Submersible external three-phase plate
Speed control method:
*PWM speed regulation: amplitude 5V 50-800HZ can be customized.
*0-5V speed regulation
*Potentiometer speed regulation: resistance range 4.7K ~ 20K
Type of power supply:
DC power supply, solar panel, battery Basic parameters (parameters can be customized)
Product Model DC55A-12120PWM
DC55A-12120VR
DC55A-12120VS
DC55A-12120S
DC55A-18160PWM
DC55A-18160VR
DC55A-18160VS
DC55A-18160S
DC55A-24160PWM
DC55A-24160VR
DC55A-24160VS
DC55A-24160S
DC55A-36160PWM
DC55A-36160VR
DC55A-36160VS
DC55A-36160S
PWM:PWM speed control (50-800HZ/5V)
VR:potentiometer speed control
VS:0~5V analog voltage signal speed control
S:Fixed speed
Rated Voltage 12V 18V DC 24V DC 36V Operating Voltage Range 10-18V
10-18V
10-30V
15-40V
Within this range, the pump can work normally Rated current 3.5A(4.5A)
3.5A(4.5A)
2.7A(3.3A)
1.8A(2.2A)
Closed outlet current (open pumping current) Input power 42W(54W)
65W(80W)
65W(80W)
65W(80W)
Closed outlet power (open pumping power) Maximum flow rate 1700L/H
1800L/H
1800L/H
1800L/H
Open-port flow rate Maximum head 12M
16M
16M
16M
Static head Minimum input power 12V-5A
18VSolar panel power supply
24V-4A
36V-3A
Description of additional functions
Jamming protection Pump stops working when jammed Water shortage/idling protection The pump will stop (8 seconds) and run (2 seconds) cyclically when the pump is out of water or idling, the protection strategy can be customized. Overload protection When the voltage is unstable or for other reasons exceeds the rated power of the pump, the pump will stop running. Reverse power connection When the positive and negative poles of the power supply are reversed, the pump stops running, and after reconnecting, it works normally. Pump driver built-in Suitable for external land use Pump driver external Suitable for high temperature or corrosive solution submersible installation Flow rate and head curve
Flow rate and head curve
Parameter test installation diagram
Note: This product does not have the function of self-priming, so when installing, you need to ensure that there is enough water in the gland cavity, i.e., when installing, you need to ensure that the center of the water pump is lower than the liquid level in the tank to ensure that the water pump can operate normally!
-